Abstract

Purpose

Continuous passive motion (CPM) is widely used for early rehabilitation after total knee arthroplasty, yet direct comparative evidence against robotic exoskeleton-assisted (REA) therapy remains scarce. This study compared the two modalities in terms of functional recovery and patient-reported outcomes.

Design/methodology/approach

A prospective, single-centre, quasi-randomised comparative study was conducted with 40 patients (20 per group) allocated by sequential alternating assignment, each receiving 20 rehabilitation sessions over four weeks. Outcomes were the 6-Minute Walk Test, passive knee ROM, VAS pain, and normalised WOMAC, analysed with ANCOVA and Bonferroni correction.

Findings

Both groups improved significantly from baseline. The exoskeleton group showed significantly greater gains in walking distance (153.15 vs 117.75 m), passive knee ROM (109.70° vs 84.25°), and pain reduction (48.05 vs 29.10 VAS points; p = 0.001 each), persisting after ANCOVA adjustment. WOMAC showed no significant between-group difference (p = 0.099).

Research limitations/implications

Allocation was sequential rather than fully randomised, the sample was single-centre, and follow-up was limited to four weeks. Larger multi-centre randomised trials with longer follow-up are recommended.

Practical implications

REA rehabilitation is a promising therapeutic alternative to CPM for early functional recovery after primary total knee arthroplasty and warrants confirmation in larger multicentre randomised trials.

Originality/value

Among the first studies directly comparing REA rehabilitation with CPM using a comprehensive outcome battery in the same post-arthroplasty population.

References:

1.
Jones CA, Beaupre LA, Johnston DW, Suarez-Almazor ME. Total joint arthroplasties: current concepts of patient outcomes after surgery. Rheumatic Disease Clinics of North America. 2007;33(1):71-86. doi:10.1016/j.rdc.2006.12.008
2.
Bini SA. Artificial intelligence, machine learning, deep learning, and cognitive computing: what do these terms mean and how will they impact health care? The Journal of Arthroplasty. 2018;33(8):2358-2361. doi:10.1016/j.arth.2018.02.067
3.
Aung YYM, Wong DCS, Ting DSW. The promise of artificial intelligence: a review of the opportunities and challenges of artificial intelligence in healthcare. British Medical Bulletin. 2021;139(1):4-15. doi:10.1093/bmb/ldab016
4.
Labraca NS, Castro-Sanchez AM, Mataran-Penarrocha GA, Arroyo-Morales M, Sanchez-Joya Mdel M, Moreno-Lorenzo C. Benefits of starting rehabilitation within 24 hours of primary total knee arthroplasty: randomised clinical trial. Clinical Rehabilitation. 2011;25(6):557-566. doi:10.1177/0269215510393759
5.
Renkawitz T, Rieder M, Handel M, Koller M, Drescher J, Bonnlaender G. Comparison of two accelerated clinical pathways after total knee replacement: how fast can we really go? Clinical Rehabilitation. 2010;24(3):230-239. doi:10.1177/0269215509353267
6.
Boese CK, Weis M, Phillips T, Lawton-Peters S, Gallo T, Centeno L. The efficacy of continuous passive motion after total knee arthroplasty: a comparison of three protocols. Knee Surgery, Sports Traumatology, Arthroscopy. 2014;29(6):1158-1162. doi:10.1016/j.arth.2013.12.005
7.
Bennett LA, Brearley SC, Hart JAL, Bailey MJ. A comparison of 2 continuous passive motion protocols after total knee arthroplasty: a controlled and randomised study. The Journal of Arthroplasty. 2005;20(2):225-233. doi:10.1016/j.arth.2004.08.009
8.
Lau CE, Chiu KY. Use of continuous passive motion after total knee arthroplasty. The Journal of Arthroplasty. 2001;16(3):336-339. doi:10.1054/arth.2001.21453
9.
Kim TK, Park KK, Yoon SW, Kim SJ, Chang CB, Seong SC. Clinical value of regular passive ROM exercise by a physical therapist after total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2009;17(10):1152-1158. doi:10.1007/s00167-009-0731-2
10.
Pongkunakorn A, Sawatphap D. Use of drop and dangle rehabilitation protocol to increase knee flexion following total knee arthroplasty: a comparison with continuous passive motion machine. Journal of the Medical Association of Thailand. 2014;97(Suppl 9):S16-S22.
11.
Mau-Moeller A, Behrens M, Finze S, Bruhn S, Bader R, Mittelmeier W. The effect of continuous passive motion and sling exercise training on clinical and functional outcomes following total knee arthroplasty: a randomised active-controlled clinical study. Health and Quality of Life Outcomes. 2014;12(1):68-78. doi:10.1186/1477-7525-12-68
12.
Zietek P, Zietek J, Szczypior K, Safranow K. Effect of adding one 15-minute walk on the day of surgery to fast-track rehabilitation after total knee arthroplasty: a randomised, single-blind study. European Journal of Physical and Rehabilitation Medicine. 2015;51(3):245-252.
13.
den Hertog A, Gliesche K, Timm J, Muhlbauer B, Zebrowski S. Pathway-controlled fast-track rehabilitation after total knee arthroplasty: a randomised prospective clinical study evaluating the recovery pattern, drug consumption, and length of stay. Archives of Orthopaedic and Trauma Surgery. 2012;132(8):1153-1163. doi:10.1007/s00402-012-1528-1
14.
Lang CE. Comparison of 6- and 7-day physical therapy coverage on length of stay and discharge outcome for individuals with total hip and knee arthroplasty. Journal of Orthopaedic & Sports Physical Therapy. 1998;28(1):15-22. doi:10.2519/jospt.1998.28.1.15
15.
Bruun-Olsen V, Heiberg KE, Mengshoel AM. Continuous passive motion as an adjunct to active exercises in early rehabilitation following total knee arthroplasty—a randomised controlled trial. Disability and Rehabilitation. 2009;31(4):277-283. doi:10.1080/09638280801931204
16.
Denis M, Moffet H, Caron F, Ouellet D, Paquet J, Nolet L. Effectiveness of continuous passive motion and conventional physical therapy after total knee arthroplasty: a randomised clinical trial. Physical Therapy. 2006;86(2):174-185.
17.
Curry AL, Goehring MT, Bell J, Jette DU. Effect of physical therapy interventions in the acute care setting on function, activity, and participation after total knee arthroplasty: a systematic review. Journal of Acute Care Physical Therapy. 2018;9(3):93-106. doi:10.1097/JAT.0000000000000079
18.
Celebi B, Yalcin M, Patoglu V. AssistOn-Knee: A self-aligning knee exoskeleton. In: 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems; 2013; Tokyo, Japan. IEEE; 2013. p. 996-1002. doi:10.1109/IROS.2013.6696472
19.
Dung Cai VA, Bidaud P, Le TT, Ibanez A, Phan XT. In search of transparency for lower limb exoskeleton devices with a new mechanical design and a robust gait phases detection method. In: 2015 IEEE International Conference on Robotics and Biomimetics (ROBIO); 2015; Zhuhai, China. IEEE; 2015. p. 1151-1156. doi:10.1109/ROBIO.2015.7418927
20.
Wehner M, Quinlivan B, Aubin PM, Martinez-Villalpando E, Baumann M, Stirling L, et al. A lightweight soft exosuit for gait assistance. In: 2013 IEEE International Conference on Robotics and Automation; 2013; Karlsruhe, Germany. IEEE; 2013. p. 3362-3369. doi:10.1109/ICRA.2013.6631046
21.
Robin W, Garone E, Innocenti B. The use of robotic devices in knee rehabilitation: a critical review. Muscle Ligaments and Tendons Journal. 2019;9(1):21-48. doi:10.32098/mltj.01.2019.07
22.
Alalwani RAM, Ghafari AS. Design and Prototyping of an Robotic Exoskeleton for Rehabilitation After Total Knee Arthroplasty. In: 2024 3rd International Conference on Automation, Robotics and Computer Engineering (ICARCE); 2024; China. IEEE; 2024. p. 55-59. doi:10.1109/ICARCE63054.2024.00018
23.
Mehrholz J, Kugler J, Pohl M, Elsner B. Electromechanical‐assisted training for walking after stroke. Cochrane Database of Systematic Reviews. 2025;(5):CD006185. doi:10.1002/14651858.CD006185.pub6
24.
Moreira L, Figueiredo J, Cerqueira J, Santos CP. A review on locomotion mode recognition and prediction when using active orthoses and exoskeletons. Sensors. 2022;22(19):7109. doi:10.3390/s22197109
25.
Rosenberg N. Walking ability after total knee arthroplasty: a comprehensive review. Cureus. 2025;17(2):e79577. doi:10.7759/cureus.79577
26.
Bhardwaj S, Khan AA, Muzammil M. Lower limb rehabilitation robotics: the current understanding and technology. Work. 2021;69(3):775-793. doi:10.3233/WOR-205012