Robotic exoskeleton-assisted rehabilitation versus continuous passive motion after total knee arthroplasty: a quasi-randomized comparative study
- 1. Al-Furat Al-Awsat Technical University, Al-Kufa, Iraq
- 2. School of Science and Engineering, Sharif University of Technology, International Campus, Kish Island, Iran
Abstract
Purpose
Continuous passive motion (CPM) is widely used for early rehabilitation after total knee arthroplasty, yet direct comparative evidence against robotic exoskeleton-assisted (REA) therapy remains scarce. This study compared the two modalities in terms of functional recovery and patient-reported outcomes.
Design/methodology/approach
A prospective, single-centre, quasi-randomised comparative study was conducted with 40 patients (20 per group) allocated by sequential alternating assignment, each receiving 20 rehabilitation sessions over four weeks. Outcomes were the 6-Minute Walk Test, passive knee ROM, VAS pain, and normalised WOMAC, analysed with ANCOVA and Bonferroni correction.
Findings
Both groups improved significantly from baseline. The exoskeleton group showed significantly greater gains in walking distance (153.15 vs 117.75 m), passive knee ROM (109.70° vs 84.25°), and pain reduction (48.05 vs 29.10 VAS points; p = 0.001 each), persisting after ANCOVA adjustment. WOMAC showed no significant between-group difference (p = 0.099).
Research limitations/implications
Allocation was sequential rather than fully randomised, the sample was single-centre, and follow-up was limited to four weeks. Larger multi-centre randomised trials with longer follow-up are recommended.
Practical implications
REA rehabilitation is a promising therapeutic alternative to CPM for early functional recovery after primary total knee arthroplasty and warrants confirmation in larger multicentre randomised trials.
Originality/value
Among the first studies directly comparing REA rehabilitation with CPM using a comprehensive outcome battery in the same post-arthroplasty population.