25-11-2026 - Others noncitable - Pages: 4 - 4
Language versions:
101
GICID: 01.3001.0056.0041
25-11-2026 - Review article - Pages: 5 - 20
Ahmed El-Housni, Zitouni Beidouri, Khalid Zarbane

The systematic review investigates the influence of FDM/FFF process parameters, particularly layer thickness, on the tribological performance of elastomeric and flexible polymer components, focusing on mechanisms through which printed architecture influences friction and wear.


Peer-reviewed studies were identified from Scopus, Web of Science and SpringerLink and ScienceDirect. Following deduplication, 665 records were screened; 155 full-text records were then assessed, yielding 103 included studies. Data were categorised as direct core, indirect tribology, mechanistic or comparator evidence. Structured quantitative comparisons and a narrative mechanistic synthesis were undertaken; conventional meta-analysis was not performed due to substantial heterogeneity and limited direct evidence.


One included study simultaneously investigated FDM-printed TPU, variation in layer thickness and tribological outcomes. Overall, the evidence indicates that layer thickness can affect surface roughness, porosity, interlayer structure and the mechanical response of polymers to shear, but the direction and magnitude of this tribological effect is not consistent across printed materials. The complete causal process-structure-tribology relationship has seldom been measured under the same experiment.


The evidence base is heterogeneous in terms of materials, process conditions, tribological protocols and outcome definitions. Most studies provide mechanistic rather than direct tribological evidence and many included records have incomplete reporting of methods.


Layer thickness should be selected in conjunction with material grade, printing temperature, speed, orientation, infill and service conditions and should be verified under the intended contact conditions.


The review distinguishes direct tribological data from mechanistic and comparator data and establishes a process-structure-tribology framework to explain layer-thickness effects in FDM elastomers.


Language versions:
193
DOI: 10.5604/01.3001.0055.9967
GICID: 01.3001.0055.9967
19-11-2026 - Original article - Pages: 21 - 41
Felipe Ribeiro Toloczko, Gilmar Ferreira Batalha, Mario Henrique Fernandes Batalha

The study investigates the geometry-induced anisotropy of five two-dimensional lattice mechanical metamaterials manufactured by fused deposition modelling (FDM). The study evaluates how cellular topology influences mechanical response under uniaxial and biaxial tensile loading to improve understanding of anisotropic behaviour in additively manufactured lattice structures.


Five lattice topologies, namely hexagonal, modified hexagonal, re-entrant hexagonal, triangular, and modified triangular, were fabricated using PLA-High Speed filament. Uniaxial tensile tests were performed at 0°, 45°, and 90°, while biaxial tensile tests were conducted using a dedicated testing device developed for this investigation. All experiments were carried out at a controlled temperature of 30°C. Strain measurements were obtained using Digital Image Correlation (DIC) to determine the deformation response and plastic anisotropy coefficients required for the experimental analysis.


The results demonstrated that cellular topology strongly influences the mechanical response, producing significant differences in stiffness, strength, yielding behaviour, and anisotropy under both uniaxial and biaxial loading. The combined experimental approach enabled more comprehensive characterisation of geometry-induced anisotropy than conventional uniaxial testing and provided reliable data to calibrate and evaluate anisotropic yield criteria.


The investigation was limited to PLA-HS specimens manufactured under identical FDM processing conditions and tested at 30°C. Future studies should extend the proposed methodology to other materials, printing strategies, temperatures, and three-dimensional lattice architectures, and investigate additional constitutive models.


The work experimentally assesses geometry-induced anisotropy in FDM lattice metamaterials by combining uniaxial and true biaxial tensile testing. The results advance understanding of the role of cellular topology in anisotropic mechanical behaviour, provide experimental data to validate anisotropic constitutive models, and support the design of lightweight architected structures.


Language versions:
1216
DOI: 10.5604/01.3001.0055.9562
GICID: 01.3001.0055.9562
Online first
25-11-2026 - Original article
Raed Abdulameer Mahmood Alalwani, Ali Selk Ghafari

Continuous passive motion (CPM) is widely used for early rehabilitation after total knee arthroplasty, yet direct comparative evidence against robotic exoskeleton-assisted (REA) therapy remains scarce. This study compared the two modalities in terms of functional recovery and patient-reported outcomes.


A prospective, single-centre, quasi-randomised comparative study was conducted with 40 patients (20 per group) allocated by sequential alternating assignment, each receiving 20 rehabilitation sessions over four weeks. Outcomes were the 6-Minute Walk Test, passive knee ROM, VAS pain, and normalised WOMAC, analysed with ANCOVA and Bonferroni correction.


Both groups improved significantly from baseline. The exoskeleton group showed significantly greater gains in walking distance (153.15 vs 117.75 m), passive knee ROM (109.70° vs 84.25°), and pain reduction (48.05 vs 29.10 VAS points; p = 0.001 each), persisting after ANCOVA adjustment. WOMAC showed no significant between-group difference (p = 0.099).


Allocation was sequential rather than fully randomised, the sample was single-centre, and follow-up was limited to four weeks. Larger multi-centre randomised trials with longer follow-up are recommended.


REA rehabilitation is a promising therapeutic alternative to CPM for early functional recovery after primary total knee arthroplasty and warrants confirmation in larger multicentre randomised trials.


Among the first studies directly comparing REA rehabilitation with CPM using a comprehensive outcome battery in the same post-arthroplasty population.


334
DOI: 10.5604/01.3001.0056.0043
16-11-2026 - Original article
Michał Puchalski

The paper demonstrates how supramolecular ordering in polylactide determines processing, final properties, product quality and degradation behaviour.


Structural knowledge from PLA research is synthesised with requirements for moulding parameters, stabilisation conditions, modification routes and assessment of degradation.


Macromolecular ordering is a decisive link between industrial processing and the quality and service behaviour of PLA products. Structural analysis can therefore guide selection of process windows and modifications even when advanced analytical equipment is not routinely available in industrial centres.


The article presents a materials-engineering synthesis rather than one standardised production trial. Future studies should establish transferable quantitative correlations for different PLA grades and processing histories.


Incorporating structural analysis into process design can improve repeatability, performance and controlled end-of-life behaviour of PLA products.


The work translates supramolecular PLA structure into concrete technological requirements for forming, stabilisation, modification and degradation control.


423
DOI: 10.5604/01.3001.0055.9818
01-11-2026 - Review article
A. Sadiq, P. Sać, N. Maciejewicz-Kamiński, A. Goszczyńska, M. El Fray

The paper reviews injectable biomaterials for trabecular bone regeneration and evaluates their capacity to provide minimally invasive delivery, adaptable mechanical behaviour and biological support for bone repair.


A structured review links trabecular-bone physiology and intrinsic healing mechanisms with conventional surgical and non-surgical fracture management. Injectable polymer systems are classified and compared in terms of composition, delivery, scaffold formation, biomedical use and responsiveness. Clinical studies and emerging four-dimensional materials activated by light, temperature or pH are also examined.


Injectable polymeric biomaterials can fill irregular defects, reduce surgical burden and create local environments conducive to tissue regeneration. Their properties may be tuned to match the biological and mechanical requirements of cancellous bone. Stimuli-responsive 4D systems extend this potential through controlled changes after implantation, although translation remains dependent on reliable performance and safety.


Available evidence is heterogeneous in material composition, experimental models and outcome measures. Future research should standardise testing, clarify degradation and host-response mechanisms and expand long-term clinical evaluation.


The review supports the selection and development of injectable scaffolds for patient-specific bone repair and identifies criteria relevant to clinical translation.


The paper connects bone physiology, established injectable polymers, clinical evidence and 4D biomaterials within one framework for trabecular-bone regeneration.


37
DOI: 10.5604/01.3001.0055.9670
Featured article
01-05-2026 - Original article
L.B. Dobrzański, L.A. Dobrzański, J. Dobrzańska, K. Rudziarczyk-Jagoda

The aim of the study is to demonstrate that SLS/SLM 3D printing of titanium alloys used for manufacturing prosthetic restorations constitutes a genuine process and material eco-innovation compared to CNC milling.


The article develops the authors’ original Dentistry 4.0 concept, in which CBCT diagnostics, CAD design, digital twin, CAM technologies, and additive manufacturing of metallic structures form an integrated model of cooperation among the dentist, dental engineer, and manufacturing centre. Material consumption, buy-to-fly ratio, material costs, total costs, tool consumption, and the potential for reuse and recycling of material according to the 6R principle were compared.


The results indicate that, in the analysed variants, CNC technology required 6 to 11 times as much raw material mass as SLS/SLM technology, with the greatest differences observed for full-arch implant-supported constructions.


The analysis was carried out for selected types of prosthetic constructions, including three-point bridges and full-arch restorations supported on teeth or implants.


The study also questions the legitimacy of using CNC for manufacturing prosthetic and implantological restorations in the context of excessive consumption of scarce critical materials, presenting a useful, real alternative in the form of SLS/SLM 3D printing using atomisation as a method of full recovery of the used material.


The results confirm that SLS/SLM of titanium alloys is not merely an alternative manufacturing method but an eco-innovation that changes the production paradigm of prosthetic restorations from subtractive, waste-generating, and tool-intensive technology to additive, resource-efficient, digital, and circular technology.


29740
DOI: 10.5604/01.3001.0055.8502
01-02-2026 - Original article
M. Ali, J.H.M. Al-Sabea, M.H. Mosa, H.M. Silva, S.J. Abbas, A.A. Zainulabdeen, Z.C. Feng

The internal combustion engines are a highly widespread technology in the transport sector, with an approximate of 1.4 billion vehicles in circulation in the world now. Although earlier studies had examined the influence of the reaction forces, gas pressure, torque and the friction force on the response of the reciprocating internal combustion engine, independently, the study offers a new analytical model that combines all these factors to demonstrate its impact on the engine.


The research utilises mechanical analysis to identify critical issues in dynamic analysis and engine design. The reaction forces on the crankshaft and the torque exerted are measured through an analysis of kinetics and free-body diagrams of a reciprocating engine system. Moreover, the ANSYS Workbench was used to model the nonlinear static response to rough contact conditions and provided more profound knowledge of the dynamics of engine operations.


Comparative findings indicate significant differences of up to 36, 15 and 34 per cent in the reaction force along the x-axis, y-axis and friction forces, respectively,  between the actual analytical and point-mass approximate calculations. ANSYS Workbench nonlinear static simulation revealed areas of critical stress and a peak displacement of about 16.7 mm, which provides useful information about improving the design of the engine.


The study was limited to reciprocating engines. The effect of thermal stress was also not considered.


The paper is a combination of reaction forces analysis in x and y axes, torque, friction forces and gas pressure to analyse their combined effects on internal combustion engines. The novelty of the study lies in its integrative methodology, which enables a strictly quantitative assessment of the joint action of multiple forces. Moreover, ANSYS Workbench is used to implement the nonlinear static response modelling during rough contact conditions, which also gives a more complete picture of the dynamics of the engine in a real-world setting.


60137
DOI: 10.5604/01.3001.0055.7919